Serial dilutions
14 min
Skills you'll build3 skills
- Calculate a cumulative dilution factor
- Calculate the destination concentration in a serial dilution step
- Predict how a transfer or diluent volume error changes a serial dilution
At the bench: Prepare a dilution using the required sample and diluent volumes
Try first
Get the idea
How a serial dilution is made
In a serial dilution each tube is made from the tube before it, after that tube has been mixed. Each step dilutes a solution that earlier steps have already diluted.
Each step has its own factor, taken from the volumes put into that tube:
step factor = (transfer volume + diluent volume) ÷ transfer volume
The tube's concentration comes from its source, the tube just before it:
destination concentration = source concentration ÷ step factor
Multiply the step factors
The total factor for any tube, compared with the original, is the product of every step factor up to and including that tube.1,2 Step factors are never added. Two 1:5 steps leave one twenty-fifth of the original, so correcting a result by 5 + 5 = 10 would give a value 2.5 times too low.
An example series starting at 240 mg/L:
| Tube | Transfer + diluent (µL) | Step factor | Total factor | Concentration (mg/L) |
|---|---|---|---|---|
| 1 | 500 + 500 | 2 | 2 | 120 |
| 2 | 250 + 750 | 4 | 8 | 30 |
| 3 | 200 + 800 | 5 | 40 | 6 |
Tube 3 is 30 mg/L ÷ 5, using tube 2 as its source. Dividing the original 240 mg/L by 5 would give 48 mg/L, which is not the concentration of any tube in this series.
When one volume is off
Calculate the factors from the volumes that were pipetted. If one transfer or diluent volume is wrong:
- That tube's step factor changes.
- Every later total factor is a product that includes it, so the error is carried into every later tube even when the later steps are pipetted correctly.2
- Calculations with the planned factors give the wrong concentration for that tube and every tube after it.
Remake the affected tube and every tube after it. Keep the tubes made before the slip.
Follow the bench demonstration
Sources for this step
References
- Bishop ML, Fody EP, Van Siclen C, Mistler JM, Moy M. Clinical Chemistry: Principles, Techniques, and Correlations. 9th ed. Jones & Bartlett Learning; 2023.
- Kingston University. Concentration of solutions: serial dilution: overview. Reviewed March 31, 2021. Accessed September 23, 2026.
Watch one
A tenfold series is planned from a solution at 80 mg/L: three tubes, each 100 µL of the previous tube plus 900 µL of diluent.
- Tube 1 was made with 100 µL of the solution and only 400 µL of diluent.
- Tubes 2 and 3 were made as planned.
What is the concentration in tube 3, and what do you do?
- Use tube 1's actual volumes: 100 µL + 400 µL = 500 µL, so its step factor is 500 ÷ 100 = 5, half the planned 10.
The step factor comes from the volumes in the tube.
- Keep the later step factors at 10 and 10.
Tubes 2 and 3 were pipetted as planned, so their step factors are unchanged.
- Multiply the actual step factors: 5 × 10 × 10 = 500. The plan assumed 1,000.
Each later tube was made from the one before, so the first step's factor is part of every later total factor.
- Tube 3 contains 80 mg/L ÷ 500 = 0.16 mg/L, twice the intended 0.08 mg/L.
The concentration is calculated from the total factor of the tubes as made.
- Remake tube 1 and then tubes 2 and 3 from it.
The pipetting error affects every tube made after it.
Your turn
Use it
Optional for this step.
Review missed questions
For reference
The rest of this step has a short briefing, a demonstration at the bench, 3 practice problems and a case in the lab.
Free account: keep your progress and get review reminders. Have one? Sign in