Releasing, calling and correcting results
15 min
Skills you'll build4 skills
- Choose release, repeat, comment, or recollection from the specimen checks and QC
- Communicate a critical result with identifiers, units, and confirmed receipt
- Call an established critical result before continuing routine work
- Correct a reported error, keep both reports, and notify the care team
At the bench: Check specimen identity and suitability before analysis · Communicate a critical result and confirm receipt · Correct a report while preserving the original result record
Try first
| Test | Result | Previous | Reference interval | Flag |
|---|---|---|---|---|
| Sodium | 144 mmol/LYesterday 06:00: 139 mmol/L | 139 mmol/LYesterday 06:00 | 135–145 mmol/L135–145 | |
| Potassium | 2.9 mmol/L LowYesterday 06:00: 4.1 mmol/L | 4.1 mmol/LYesterday 06:00 | 3.5–5.1 mmol/L3.5–5.1 | Low |
| Chloride | 119 mmol/L HighYesterday 06:00: 104 mmol/L | 104 mmol/LYesterday 06:00 | 98–107 mmol/L98–107 | High |
Specimen: H 8, L 10, I 1. Serum, drawn from the left arm; saline infusing in the left forearm
Get the idea
Four checks before release
A result is released only after four checks pass:
- the specimen belongs to the patient
- the specimen is fit for the test
- the run was in control
- the result is consistent with the patient's history
Each check covers something the others cannot. Acceptable QC shows the analyzer measured its control material correctly. It cannot detect infusion fluid, carryover or hemolysis in one patient's tube.1,2
The checks lead to one of five dispositions:
| Disposition | When |
|---|---|
| Release | Identity, specimen, run and history are all acceptable |
| Repeat | The question is about the measurement, and the specimen is suitable |
| Release with a comment | The procedure allows the result with a stated limitation |
| Keep pending release with a comment | A check is still open, such as identity or a question to the ward |
| Redraw | The specimen itself is wrong: contamination, hemolysis from the draw above the limit, a clot, the wrong tube |
Critical results come first
When a result meets a value on the laboratory's critical list, the laboratory alerts the person responsible for the patient at once. Routine verification and any repeat the procedure does not require come after the call.2,3
- Identify yourself and the person receiving the result.
- Give two patient identifiers, the test, and the value with its unit.
- When the procedure calls for read-back, listen to the full read-back. Correct any mismatch in the identifier, value or unit before ending the call.
The record shows the date and time, the result and the person notified. If the first contact cannot be reached, the escalation list in the procedure is followed until someone authorized accepts the result.3,6
Corrected reports
When the laboratory finds an error in a result already reported, it:2,6
- promptly notifies the person who ordered the test
- promptly issues a corrected report
- keeps both the original and the corrected report
Clinicians may already have acted on the first value, so the report shows that it was corrected, and the original stays traceable.2,6
Follow the bench demonstration
Sources for this step
References
- Krasowski MD. Educational case: hemolysis and lipemia interference with laboratory testing. Acad Pathol. 2019;6:2374289519888754. doi:10.1177/2374289519888754
- Centers for Medicare & Medicaid Services. 42 CFR §§493.1256 and 493.1291. Electronic Code of Federal Regulations. Accessed September 23, 2026.
- Clinical and Laboratory Standards Institute. Management of Critical- and Significant-Risk Results. 1st ed. CLSI guideline GP47. Clinical and Laboratory Standards Institute; 2015. Accessed September 23, 2026.
- Henriksen K, Hall KK. Say it again. PSNet. Agency for Healthcare Research and Quality. Published June 1, 2011. Accessed September 23, 2026.
- College of American Pathologists. Laboratory General Checklist. COM.30000, COM.30100. June 4, 2020. Accessed September 23, 2026.
- Centers for Medicare & Medicaid Services. State Operations Manual, Appendix C: Survey Procedures and Interpretive Guidelines for Laboratories and Laboratory Services. Updated January 23, 2026. Accessed September 23, 2026.
Watch one
You are verifying a batch of 40 routine outpatient chemistries when an emergency department potassium comes up at 6.8 mmol/L.
- The hemolysis index is 20, and your procedure's potassium limit is 50.
- The label matches the order with both identifiers, and QC is acceptable.
- Your laboratory's critical limit for potassium is 6.2 mmol/L or above, and the procedure calls without a repeat.
What do you do?
- Check the specimen: the index of 20 is below the potassium limit of 50, identity matches, and QC is acceptable.
A critical call on a compromised specimen reports an artifact to the care team, so the quick specimen checks come first.
- Compare with the critical list: 6.8 mmol/L is at or above 6.2 mmol/L, so the result is critical.
The critical value list determines whether the result needs an immediate call.
- Stop the batch: the 40 routine results wait until the call is done.
Minutes matter for a critical potassium, and routine results can wait a few minutes.
- Call the emergency department: give your name, confirm the receiver's name, then two identifiers, potassium and 6.8 mmol/L.
Two identifiers link the result to one patient, and the unit prevents the number from being misread.
- Take the read-back, confirm it matches, and record the date, time, result and receiver before returning to the batch.
The read-back shows what the receiver wrote down, and the record shows the call was made in time.
Your turn
Use it
Optional for this step.
- An adult man, 0318204, in the emergency department has a basic metabolic panel.
- The label has his name and MRN, matching the order.
- The hemolysis index is 15, below the potassium limit of 50, and QC is acceptable.
- Potassium, BUN and creatinine fail the delta check against his clinic panel from 2 days ago.
- Your laboratory's critical limit for potassium is 6.2 mmol/L or above, and the procedure calls without a repeat.
- Twenty-five routine results are waiting in your queue.
| Test | Result | Previous | Reference interval | Flag |
|---|---|---|---|---|
| Sodium | 136 mmol/L2 days ago: 138 mmol/L | 138 mmol/L2 days ago | 135–145 mmol/L135–145 | |
| Potassium | 6.9 mmol/L Critical2 days ago: 4.4 mmol/L | 4.4 mmol/L2 days ago | 3.5–5.1 mmol/L3.5–5.1 | Critical |
| Chloride | 101 mmol/L2 days ago: 103 mmol/L | 103 mmol/L2 days ago | 98–107 mmol/L98–107 | |
| BUN | 58 mg/dL High2 days ago: 22 mg/dL | 22 mg/dL2 days ago | 8–24 mg/dL8–24 | High |
| Creatinine | 3.10 mg/dL High2 days ago: 1.20 mg/dL | 1.20 mg/dL2 days ago | 0.74–1.35 mg/dL0.74–1.35 | High |
Specimen: H 15, L 10, I 1. Serum; department confirmed collection at 14:05 from an arm with no infusion
Every check behind the delta failure passed, and the other results changed along with the potassium:
- Identity was confirmed.
- No infusion was in the arm.
- The index was low, and QC was acceptable.
- BUN and creatinine rose over the same 2 days.
The specimen is acceptable and the result is critical, so the call comes before the routine queue.
Review missed questions
For reference
The rest of this step has a short briefing, a demonstration at the bench, 3 practice problems and a short case.
Free account: keep your progress and get review reminders. Have one? Sign in