Skip to content
LatticeMLS, Home

Add your earlier progress to your account?

From before you signed in, this browser has:

Which plan do you want to keep?

You changed your plan before signing in, and those changes don't match the plan saved on your account.

SettingSaved planPlan changes

Study progress is waiting to be saved

The testing cycle and patient identity

12 min

Skills you'll build2 skills
  • Locate an error in the preanalytic, analytic, or postanalytic phase
  • Verify patient and specimen identity before testing or giving a result

At the bench: Check specimen identity and suitability before analysis

Try first

Try first

A potassium comes off the analyzer high. The serum is visibly red, the hemolysis index is raised, and both levels of quality control on the run were acceptable. Where in the testing cycle did the problem begin?

Keep going to see the reasoning.

Keep going to see the reasoning.

Right. Keep going to follow the reasoning.

Keep going to see the reasoning.

Get the idea

Three phases

Every result passes through three connected phases, often called preanalytic, analytic and postanalytic. ISO standards name them preexamination, examination and postexamination. Together they make up the path of workflow, which starts with the patient and ends when the result is reported and interpreted.1

PhaseCoversTypical failures
PreanalyticTest selection, patient identification, collection, labeling, transport and receiptWrong patient, wrong tube, short fill, clot, hemolysis, delay
AnalyticThe measurement itselfFailed quality control, calibration error, reagent or instrument fault
PostanalyticReview, reporting and interpretationTranscription error, wrong reference interval, late critical call

Identifying the phase of error

Naming the phase shows where to investigate. A problem often appears in a later phase than the one where it began.

  • Hemolysis is the usual example. The analyzer's index reports it during measurement, and in most cases the red cells broke during collection or transport, so changing reagents or recalibrating does not correct it.1,2
  • Acceptable quality control shows the measuring system worked. It does not show whether one patient's specimen was acceptable for testing.1

Identity at every handoff

The first preanalytic check is identity, and it continues through the whole cycle.

  • A specimen is linked to a patient by at least two person-specific identifiers, such as full name with date of birth or medical record number.3,4
  • A room or bed number is never an identifier, because patients move and rooms are reused.4
  • The label goes on the tube in the patient's presence, with the name, a unique identification number, the collection date and time and the collector's initials.1,3

The same two identifiers are checked again each time the specimen or its result changes hands:3,4

  • at receipt, against the order
  • before testing
  • whenever a result is given out, including by phone

A name alone is one identifier, and two patients in the same hospital can share it. An unlabeled specimen, or one whose label and request do not match, is rejected under the laboratory's identification policy. The requester is told promptly, and a new specimen is requested.1

Follow the bench demonstration

Sources for this step
References
  1. World Health Organization. Laboratory Quality Management System: Handbook. World Health Organization; 2011:11,65-66. Accessed September 23, 2026.
  2. Simundic AM, Bölenius K, Cadamuro J, et al. Joint EFLM-COLABIOCLI recommendation for venous blood sampling. Clin Chem Lab Med. 2018;56(12):2015-2038. doi:10.1515/cclm-2018-0602
  3. Clinical and Laboratory Standards Institute. Patient and Laboratory Specimen Identification Processes. 1st ed. CLSI standard PRE01. Clinical and Laboratory Standards Institute; 2024. Accessed September 23, 2026. https://clsi.org/shop/standards/pre01/
  4. The Joint Commission. Two patient identifiers: understanding the requirements. Updated April 21, 2026. Accessed August 28, 2026.

Watch one

An outpatient serum collected at a clinic at 09:00 reaches the laboratory unspun at 15:30.

  • Potassium is high and glucose is low.
  • The hemolysis index is not raised.
  • Both control levels on the run were acceptable, and calibration is current.

Where did the error begin?

  1. Check the analytic evidence: both controls acceptable and calibration current, so the measuring system worked on this run.

    The run's QC and calibration records are the quickest check of the analytic phase.

  2. Check the indices: hemolysis is not raised, so hemolysis does not explain the potassium.

    A raised potassium on red serum would suggest hemolysis.

  3. Read the collection and receipt times: six and a half hours with serum in contact with the cells.

    Time and handling records show what happened to the tube before it was measured.

  4. Match the pattern: a high potassium with a low glucose fits delayed separation.

    Cells left in contact with serum continue to consume glucose and leak potassium.

  5. The error arose before measurement: preanalytic. Apply the laboratory's stability limit and request a new specimen.

    The phase is named for where the error began, which is also where the correction belongs.

A preanalytic error: delayed separation during transport.

Practice this skill

Your turn

Problem 1 of 3 · Hints available

Which pair of identifiers is suitable for matching a specimen to the patient?

Incorrect. A room number describes a location, and patients move between rooms. The second identifier has to belong to the person, such as a date of birth or medical record number.

Correct. The name and the medical record number both belong to the patient, so they are two person-specific identifiers, and the label keeps them linked to the specimen through testing.

Incorrect. One identifier checked in two places is still one identifier. Two patients who share a name would both match.

Hint
  1. An identifier has to belong to the person, wherever they are.
  2. A room number describes a place, and a patient can move rooms.
  3. Look for the pair made of two different facts about the person.

Review Ordering, identification, and acceptability

Problem 2 of 3 · Hints available

Which finding indicates a problem in the analytic phase?

The analyzer detects the hemolysis. The red cells broke during collection or transport, which makes it a preanalytic problem.

Called collection hemolysis an analytic error

Most hemolysis occurs during collection or transport. The analyzer only measures it and reports a hemolysis index. Classifying it as an analytic error points the investigation at reagents and calibration, and the collection practice that caused it goes uncorrected.

The measurement was finished and verified, so the delay came in reporting, which is postanalytic.

Controls test the measuring system. When both levels fail together, the fault is in the measurement: reagent, calibration or instrument.

Hint
  1. The analytic phase is the measurement itself.
  2. Ask which finding shows a fault in the measuring system, regardless of the specimen tested.

Review The testing cycle

Problem 3 of 3 · On your own

A nurse on 5 West phones for the hemoglobin of patient Dana Reade. The laboratory system shows two inpatients named Dana Reade, one on 5 West and one on 3 East. What do you do before giving a result?

Two person-specific identifiers link the call to one patient. Only when both match the record do you give the result.

A unit is a location, and patients move between units. Location cannot distinguish two patients with the same name.

A name is one identifier, and here it matches two patients. The result could go to the wrong person's care.

Matched a result to a patient by name alone

A name is one identifier, and two patients can share it. Giving or filing a result after matching the name alone can place one patient's value in another's record or give a caregiver the wrong result. Two person-specific identifiers, such as name with date of birth or medical record number, link a specimen to one patient.

That discloses a second patient's result and leaves identification to guesswork. Confirm identity first, then give one result.

Review Ordering, identification, and acceptability

Use it

Optional for this step.

For reference

Sources checked